4 Χρόνια 5 Μήνες πριν #168603 από KYRMI
Re:RDS ravelli HRV120 δημιουργήθηκε από KYRMI
Για σας ξέρει κάποιος τον κωδικό rds της ravelli HRV 120. Δεν είναι C2

Παρακαλούμε Σύνδεση ή Δημιουργία λογαριασμού για να συμμετάσχετε στη συζήτηση.

Περισσότερα
4 Χρόνια 5 Μήνες πριν #168606 από ΚΩΣΤΑΣ ΠΗΧΑΣ
Απαντήθηκε από ΚΩΣΤΑΣ ΠΗΧΑΣ στο θέμα Re:RDS ravelli HRV120
ΑΝ εννοεις στο κρυφο μενου μπαινεις με Α9 ΚΩΔΙΚΟ.ΔΙΑΒΑΣΕ ΚΑΙ ΓΙΑ ΤΟ RDS ΕΙΝΑΙ ΑΓΓΛΙΚΑ (κανε μεταφραση) This particular RDS adjustment method allows for the calibration of the parameters related to the oxygen intake for
combustion in a more or less automatic manner. A detail of the new firmware is the presence of the “Regular sist.
RDS” warning on putting the stove into function and every time it is intended to light/extinguish it;
in any case, the message which is seen for a few seconds in no way prejudices its function.
This signal will only disappear when the installer has carried out the following operations.
- Start the RDS system adjustment process: the icon to be selected to start the RDS adjustment process is the
following and is situated in the main menu (brief pressure on the OK button from the STAND-BY state). Click on
the icon and insert the password “C2“ to start the
process (illustration below).
_ Extractor revolutions adjustment in the various phases of turning the stove on: The “RDS system adjustment”
illustration indicates the various progressive phases from lighting up to the working condition in the “machine status”.
These phases are: Lighting up/Awaiting flame, Flame present, Working. It is possible to adjust the rpm in the
“extractor revolutions” choice in every phase, with buttons 1(-) e 2(+) in order to obtain the best functional conditions in
the different states.
Awaiting flame: as soon as this phase is reached, the rpm number appears (second line of the screen), the
variation in value that the installer sets with buttons 1 and 2 of the display has the aim of improving the
lighting up process;
Flame present: as soon as it passes into this phase, the rpm number appears (second line of the
screen), the variation in value that the installer sets with buttons 1 and 2 of the display has the aim of
improving stabilization of the flame;
Work: the stove reaches maximum, and an acoustic signal accompanied by the appearance of the rpm
(second line of the screen) indicates the possibility of varying the value with the aim of perfecting combustion
in order to obtain the ideal flame. From this moment, the 20’ timer starts to wind down; this timing is
useful to the debimeter for reading a correct value (hot RDS adjustment) and to work in optimum manner.
_ Modifications parameter block and flow sampling: two minutes before the timer ends, the system blocks the
modification of the rpm (revolutions per minute) and starts to sample the debimeter reading.
_ End test and automatic saving of the various power settings: when the stove passes into the classical standby
screen, the system has found the flow value at maximum power (specific value for that installation and for the type of
pellet used) and, in automatic, all the lower values are calculated (0,05 m/s for the flow and 100 rpm for the extractor
revolutions). Always in automatic, the RDS system is re-activated with the new parameters.
NB: In the event of an alarm during the process, the system exits the calibration phase; It will, therefore,
be necessary to restart it to eliminate the “Adjust sist. RDS” signal. Each time the firmware is updated, the
obligatory restoration of the parameters phase will make the “Adjust sist. RDS” signal re-appear; it will,
therefore, be necessary to restart the calibration test.